TitleProduct

Single Phase AC Voltage Current Transducer

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-20 23:42

  • Browse the number:

    140

Send an inquiries
+
Beijing GFUVE Electronics Co., Ltd.
Contactaixin:

Mr. Andy Huang(Mr.)  

Email:

telephone:

phone:

Arrea:

Beijing

Address:

Bldg,1-1006,Joy Mansion,No.99 Chaoyang North Road, Chaoyang District, Beijing, China 100025

Website:

http://guangfuhui.chinamaysmi.com/

+


FUD-I/U SINGLE PHASE AC VOLTAGE CURRENT TRANSDUCER
Changing the measured AC current/voltage to the DC current/voltage output according to the linear scale Excellent temperature characteristic and good working stability Configuration compactness and briefness.

FEATURES
Single phase current / voltage transducer
AC current / voltage transducer
Accuracy class can reach 0.2%
AC input range can be customized
DC output range can be customized
 
MODEL DESCRIPTION

FUD-Type-Input-Power Supply-Output
Type I: Single phase AC current transducer
U: Single phase AC voltage transducer
Ir: Single phase AC real RMS current transducer
Ur: Single phase AC real RMS voltage transducer
AC input A1: 0-1A, A2: 0-5A, A3: 0-10A.
V0: 0-70V, V1: 0-120V, V2: 0-250V,
V3: 0-300V, V4: 0-450V, V5: 0-500V.
Power supply P1: AC110V±10%, P2: AC220V±15%, P3: AC110V-330V.
DC output O1: 0-5V, O2: 1-5V, O3: 0-20mA, O4: 4-20mA, O5: RS485
Example 1: FUD-I-A2-P2-O4
FUD series single phase AC current transducer Input: AC0-5A
Power supply: AC220V±15%
Output: DC4-20mA
Example 2: FUD-Ur-V3-P2-O4
FUD series single phase AC real RMS voltage transducer Input: AC 0-300V
Power supply: AC220V±15%
Output: DC4-20mA
Please check the type, input range, output range and power supply when your order the product.

TECHNICAL INDEX

Technical Index
Standard GB/T 13850-1998, IEC688:1992
Accuracy 0.2%, 0.5%
Consumption ≤3VA
Accuracy drift Annual variation < 0&period;2&percnt;
Insulation voltage AC 2kV&sol;min&period;1mA &lpar;Between input- output &sol; power&rpar;
Insulation resistance ≥20M&ohm; &lpar;DC500V&rpar;
Surge voltage 5KV &lpar;Peak value&rpar;&comma; 1&period;2&sol;50μs
Response time ≤350ms
Input range AC 0-10A &comma;AC 0-500V&lpar;Option&rpar;&comma; 50&sol;60Hz
Absorbed power <0&period;5VA&sol;450V&comma; <0&period;2VA&sol;100V&comma; <0&period;1VA&sol;5A
Overload Current&colon; 2 times continuous&comma; 30 times &sol;1s&semi; 
Voltage&colon; 2 times continuous
Load resistance Current output&colon; RL≤550&ohm;
Voltage output&colon; RL≥2k&ohm;
Working environment Temperature&colon; -10 to &plus;50ºC
RH&colon; 20-90&percnt;&comma; without condensation
Storage conditions Temperature&colon; -40 to &plus;70ºC
RH&colon; 20-95&percnt;&comma; without condensation
Installation 35mm DIN sliding-way or M4 screws
Dimension 55mm x 75mm x 120mm